Operation
Operating Manual PNOZ mmc7p CC
1003066-EN-01
15
Operation
When the supply voltage is switched on, the PNOZmulti safety system copies the configu-
ration from the chip card.
The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up on the base unit.
The expansion module PNOZ mmc7p CC is configured and started automatically.
Messages
Legend:
LED on
LED off
LED Key
Power
Green Supply voltage is present
} Supply voltage is not present
RUN
Green Bus connection available
} Bus connection is not available
} Status: timeout
} No supply voltage at the fieldbus module PNOZ mmc7p CC
L Err
Red Fault detected: Wrong station address or transmission rate
} Bus connection available
} No supply voltage at the fieldbus module PNOZ mmc7p CC
7