Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
8-1
8.1 Technical details
8 Technical details
88000Technical detailsTechnical details8-8.1Technical details8100Technical details8-
Technical details
Electrical data
Supply voltage (U
B
)
via base unit
24 VDC
Voltage tolerance -15% ... 20%
Power consumption at U
B
via base unit Typ. 1 W
Residual ripple U
B
+/- 5 %
Times
Supply interruption before de-energisation Min. 20 ms
Configurable switch-off delay 0 ... 2500 ms
Response time
f ≥ 100 Hz:
Configurable switch-off delay +
Switch-off delay PNOZ m1p +
f < 100 Hz:
Configurable switch-off delay +
Switch-off delay PNOZ m1p +
10 ms
10 ms + 1/f
Proximity switch input
Number of inputs 4 (2 axes)
Signal level at the inputs
“1” Signal (high)
“0” Signal (low)
11 V … 30 V
-3 … 5 V
Input resistance 3 kOhm
Input's frequency range 0 … 3 kHz
Configurable monitoring frequency
Without hysteresis
With hysteresis
0.1 Hz ... 3 kHz
0.2 Hz ... 3 kHz
Connection type Cage clamp terminals
Cross section of external conductors
Rigid single-core, flexible multi-core or multi-core
With crimp connector
Flexible multi-core with plastic sleeve
0.5 ... 2.5 mm
2
0.5 ... 1.5 mm
2
Incremental encoder input
Number of inputs 2 (2 axes)
Supply voltage for incremental encoders 5 V +/-10 %, typ. 30 mA
Signal level at the inputs 0.5 V
ss
… 5 V
ss
Phase position for the differential signals A, /A and B 90° ±30°
Overload protection -30 V ... +30 V
Input resistance 10 kOhm
Input's frequency range 0 … 500 kHz
Configurable monitoring frequency
Without hysteresis
With hysteresis
0.1 Hz ... 500 kHz
0.2 Hz ... 500 kHz
Connection type RJ-45 female connector
Environmental data
Airgap creepage DIN VDE 0110-1, 04/97
Vibration in accordance with EN 60068-2-6, 04/95
Frequency:
Amplitude:
10 ... 55 Hz
0.35 mm
Climatic suitability DIN IEC 60068-2-3, 12/86
DIN CEI 60068-2-3, 12/86
EMC EN 60947-5-1, 01/00
Comentários a estes Manuais