6.2 Preparing for operation
6 Commissioning
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
6-2
6.2Preparing for operation6200Preparing for operation6-
6.2.1 Connection of proximity switches
Connection of proximity switches6-Drehzahlwaechter_Betriebsb_Naeherungssch_BA
Proceed as follows when connecting proximity switches:
Terminals I10 and I11: connect the proximity switch for axis 1
Terminals I20 and I21: connect the proximity switch for axis 2.
If only one axis is to be monitored, either terminals I10 and I11 or ter-
minals I20 and I21 will remain free.
When connecting incremental encoders and proximity switches on an
axis:
– Terminals I10: connect proximity switch for axis 1 (I11 is not used)
– Terminals I20: connect proximity switch for axis 2 (I21 is not used)
The proximity switch must always be connected to a 0 V terminal of
the speed monitor. The 0 V terminals are connected internally.
Connect proximity switch to 24 VDC of the power supply or the speed
monitor (the 24 V terminals of the speed monitor are connected inter-
nally)
Fig. 6-2: Connection to proximity switch