PSENim1
OperatingManualPSENim1
21381EN02
5
INFORMATION
Thisgivesadviceonapplicationsandprovidesinformationonspecialfea
tures.
TheinterfacePSENim1
Oneormorepressuresensitiveprotectivedevices(safetymatsandsafeedges)canbe
connectedtotheconfigurablecontrolsystemPNOZmultiandevaluatedusingtheinterface
PSENim1.
OnlypressuresensitiveprotectivedevicesthathavebeenapprovedbyPilzmaybecon
nectedtothePSENim1.Detailscanbefoundinthecertificateshowingapprovedpressure
sensitiveprotectivedevices.
Onlypressuresensitiveprotectivedeviceswithoutinstalledterminatingresistorsaresuit
able.
Suitableevaluationdevicesarethosebaseunitsfromtheconfigurablecontrolsystem
PNOZmultithatarelistedinthecertificateshowingapprovedpressuresensitiveprotective
devices.AndtheexpansionmodulePNOZmi1p.
Youmustalsoreferto
}
TheoperatingmanualsprovidedwiththePNOZmultiunits
}
Thechapterentitled"SafetyMat/SafeEdge"inthe"SpecialApplications"document
}
Theinstallationmanualanduserinformationprovidedbytherespectivesafetymat/safe
edgemanufacturer
Foryoursafety
}
Onlyinstallandcommissiontheunitifyouhavereadandunderstoodtheseoperating
instructionsandarefamiliarwiththeapplicableregulationsforhealthandsafetyatwork
andaccidentprevention.
EnsureVDEandlocalregulationsaremet,especiallythoserelatingtosafety.
}
Anyguaranteeisrenderedinvalidifthehousingisopenedorunauthorisedmodifica
tionsarecarriedout.
Unitfeatures
}
1dualpoleinputforconnectingthetestpulseoutputsfromPNOZmultibaseunits
}
Connectionoptionformax.5groupsofpressuresensitiveprotectivedevices
}
Eachgroupofpressuresensitiveprotectivedevicescanincludeamax.of5pressure
sensitiveprotectivedevicesconnectedinseries.