Operation
Operating Manual PNOZ mm0p-T
1002704-EN-01
20
Operation
Messages
The PNOZmulti control system is ready for operation when the "POWER" and "RUN" LEDs
on the base unit are lit continuously.
Display elements
Status indicators
Legend:
LED on
LED flashes
LED off
Display elements for device diagnostics
Basis Fault
RUN DIAG FAULT IF-
AULT
OFAULT INFO
The existing user program has been deleted.
External error on the base unit, leading to a safe
condition, e.g. chip card not inserted
External error on the base unit outputs, e.g. short
across the contacts, leading to a safe condition.
Internal error on the base unit
Internal error on the base unit (inputs)
Internal error on the base unit (outputs)
Base unit in a STOP condition
External error on the base unit inputs, which does
not lead to a safe condition, e.g. partially operated
External error on the outputs of the base unit, which
does not lead to a safe condition, e.g. feedback
input defective.
Base unit switches from a RUN condition to a
STOP condition or a new project is downloaded.
New project is present.