Pilz PNOZ ms2p TTL coated version Manual do Utilizador Página 23

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 45
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 22
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
5-3
5.2 Connecting the base unit and expansion modules
5 Installation
5.2Connecting the base unit and expansion modules5200Connecting the base unit and expansion modules5-Montage_multi_Modul_verbind_rechts_BA
Connect the base unit and the expansion modules as described in the
operating manuals for the base modules.
` The terminator must be fitted to the last expansion module
` Install the expansion module in the position configured in the PNOZ-
multi Configurator.
Montage_multi_Anzahl_Module_Drehzahlwaechter_BA
You can install a maximum of 4 speed monitors to the right of the base
unit.
Montage
Base unit
Expansion module 1 Expansion module 8
774639: Jumper 779110: Terminator
Speed monitor
max. 4 Speed monitors
Vista de página 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 44 45