9-1
9.1 Safe standstill monitoring
9 Application Examples
99000Application ExamplesApplication Examples9-9.1Safe standstill m onitoring9100Safe standstill monitoring9-Applikationsbeispiel_DZE_Sichere Stillstandsüberwachung-PNOZ ms2p
Safe standstill monitoring
Configuration in the PNOZmulti Configurator
` Standstill: depending on requirement
` Speed n1: greater than the maximum permitted speed.
If the "Overspeed" output (see red marking) = "0", either the maximum
permitted speed has been exceeded or the speed monitor has recog-
nised a fault.
"Overspeed" output = "0" must lead to the shutdown of the relevant ax-
is.