7.4 Enter overrun
7 Commissioning
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-20
Fig. 7-19: Enter overrun
Using the keys , select the overrun that is specified on the type la-
bel of the press brake.
The permitted value range is 2 ... 14 mm, in 2 mm steps.
Finish the entry using the <ENTER> key.
The PSENvip prompts you to confirm that you accept the new over-
run:
Within 3 seconds, press the key .
You can exit the menu at any time without confirming the entry by
pressing <ESC>. In this case, the previous value for the overrun will
be retained.
INFORMATION
The PSENvip will need to be restarted if the entry
- Was invalid
- Took longer than 10 s.
NOTICE
Once the overrun has been entered, you will have to perform a
function test on the safety device (see section entitled "Function
test of the safety device").
SYSTEM OK
OSSD OFF
SETUP
Overrun: 10 mm
Vista de página 101