Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
4-1
4.1 Overview
4 Function description
44000Function descriptionFunction description4-4.1Overview4100Overview4-Funktion_Ueberblick_P_Variante
The PSENvip is a camera-based protection system for press brakes. It
consists of a transmitter and receiver, which are fixed to the moving part
of the press brake, the upper die. The detection zone between the trans-
mitter and receiver monitors the immediate danger zone below the mov-
ing upper tool.
The detection zone moves with the upper die, providing mobile safe-
guarding of the danger zone. If an object encroaches into the detection
zone, both output signal switching devices (OSSD1, OSSD2) on the
PSENvip will switch to the OFF-state. The safety system will use these
signals to initiate stopping of the press stroke.
Fig. 4-1: Press brake with PSENvip
1: Upper tool
2: Upper die
3: Receiver
4: Detection zone
5: Lower tool
6: Transmitter
Funktion_Gesamtsystem_P_Variante
The PSENvip is part of an overall system comprising
PSENvip transmitter and receiver
Programmable safety system PSS 4000
CNC controller
Signals from incremental encoders for defining the position and
speed
External operator elements or signals (foot switch, reset button for re-
duced protected field or setup mode, E-STOP pushbutton)
Comentários a estes Manuais