4.3 Overrun
4 Function description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-10
4.3Overrun4300Overrun4-Funktion_Nachlaufweg_Allgemein
The max. overrun is a press brake variable that will depend on the ma-
chine type. Once the closing movement has stopped, the max. overrun
must not be exceeded.
The overrun is entered during configuration via the keypad on the
PSENvip receiver.
Funktion_Nachlaufweg_P_Variante
Normally, the factory-assigned overrun is sufficient and does not have
to be configured.
Funktion_Nachlaufweg_Warnung_3
INFORMATION
Please refer to chapter 11, "Technical Details", for more informa-
tion about the input area of the overrun.
Details on how to enter the overrun are described in Chapter 7,
“Commissioning”, section entitled “Enter overrun”.
WARNING!
If you require a different overrun path than the factory-set path,
then use the value indicated by the manufacturer on the name-
plate of the press brake, or a higher value.
If you enter a lower value for the overrun, the protected field will
also be reduced to an unpermitted level.
Failure to comply could result in a hazardous situation, which
could lead to serious injury and death.