Assembly
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland
Telefon +49 711 3409-0, Telefax +49 711 3409-133, E-Mail: [email protected]
17
English
4.2 Hollow shaft version
4.2.1 Requirements
As the installation is application-dependent, the following instructions do not
claim to be exhaustive.
The measuring system should be installed on a greaseless shaft.
The clamping ring fixing should prevent axial slippage of the measuring
system on the drive shaft, see Figure 3.
Additional measures may be required to prevent axial slippage of the
measuring system.
The clamping of the measuring system must not have an axial load.
The screw on the clamping ring must be tightened to 3 Nm using a
torque wrench.
The screw on the clamping ring must be secured to stop it coming loose
unintentionally.
Positive locking using a parallel key/groove combination should prevent
radial slippage of the measuring system on the drive shaft; the
measuring system must be fixed to the drive side using a dowel pin, see
Fig. 4.
Fig. 3: Friction locking