Pilz PSENvip RL D P Manual do Utilizador Página 142

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 141
10.3 PNOZmulti
10 System Connections
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
10-12
10.3PNOZmult i10300PNO Zmulti10 -Systemanbindung_PNOZmulti
The following example illustrates a user program in the PNOZmulti Con-
figurator.
For the sake of clarity, the wiring diagram does not show the PNOZmulti
supply voltage nor any other signals (see "Overview" section).
10.3.1 Configuration of the inputs and outputs (e.g. PNOZ m1p)
Configuration of the inputs and outputs (e.g. PNOZ m1p)10-Systemanbindung_PNOZmulti_Belegung
NOTICE
Please refer to the safety guideline given in the "Overview" sec-
tion in this chapter.
INFORMATION
For a description of the user program please refer to the
PNOZmulti Configurator's online help.
Input/Output Designation Description
A1.i0 OSSD1 OSSD1 output on the PSENvip
A1.i1 OSSD2 OSSD2 output on the PSENvip
A1.i2 Overrun_Channel1 Overrun measurement output 1 on the PSENvip
A1.i3 Overrun_Channel2 Overrun measurement output 2 on the PSENvip
A1.i4 Standard Standard protected field mode
A1.i5 Box Box bending protected field mode
A1.i6 Backgauge Back gauge protected field mode
A1.i7 Box_Backgauge Box bending with back gauge protected field mode
A1.i9 Safety_Speed Safe speed = creep speed signal
A1.i10 PSENvip_Guard_On Switches the Power Off input on the PSENvip
A1.o0 Protection_Mode1 Protected field mode input 1 on the PSENvip
A1.o1 Protection_Mode2 Protected field mode input 2 on the PSENvip
A1.o2 PSENvip_Off Power Off input on the PSENvip
A1.o3 Overrun_End Signals the end of the overrun measurement
Vista de página 141