Pilz PSENvip RL D P Manual do Utilizador Página 97

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 96
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-13
7.2 Initial commissioning
7 Commissioning
7.2.2 Adjustment template with bracket
Adjustmen t template with bra cket7-Inbetriebnahme_Erstinbetriebnahme_Justageschablone_mit_Traeger
An adjustment template screwed to a suitable bracket is also available
as an accessory. This bracket is not supplied with the system.
Fasten the template to the bracket using half length taper-grooved
dowel pins and cylinder head bolts (see illustration).
Fig. 7-11: Adjustment template to attach to bracket
1: Ø 3 mm DIN 1472 half length taper-grooved dowel pin
2: M3 x 10 cylinder head bolts
3: Ø 3 mm DIN 1472 half length taper-grooved dowel pin
Attach the bracket to the upper tool clamp.
Fig. 7-12: Adjustment template with bracket
1: Bracket
10
45
65
Ø 3
+0,1
Ø 3,4
Ø 3,4
Ø 3
+0,1
1
3
2
1
Vista de página 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 156 157

Comentários a estes Manuais

Sem comentários