7.2 Initial commissioning
7 Commissioning
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-2
7.2Initial comm issioning7200Initia l commissioning7-
7.2.1 Align transmitter and receiver
Align transmitter and receiver7-Inbetriebnahme_Erstinbetriebnahme_Ausrichten
Please note the following when aligning the transmitter and receiver:
Once installed, the transmitter and receiver must be exactly aligned
to each other and to the tip of the upper tool. The vertical and hori-
zontal alignment is performed using adjustment templates and is dis-
played on the receiver.
The transmitter and receiver must also be aligned after changing ei-
ther the PSENvip transmitter or receiver.
7.2.1.1 Prepare for alignment
Prepare for alignment7-Inbetriebnahme_Erstinbetriebnahme_Ausrichtung_vorbereiten
Please note the following when preparing for alignment:
Transmitter and receiver must be installed correctly on the press
brake (see Chapter 5, "Installation") and electrically wired (see Chap-
ter 6, "Wiring").
An upper tool must be fitted to the right and left-hand edge of the
press brake.
Switch on the supply to the PSENvip.