Pilz PSENvip RL D P Manual do Utilizador Página 82

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 81
6.2 Connections
6 Wiring
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-6
6.2.2 Transmitter
Transmitter6-Funktion_Geraete_Sender_Stecker
The top of the transmitter has a 4-pin M12 connector.
Verdrahtung_Anschluss_Sender
Fig. 6-5: Pin assignment of transmitter
The transmitter is connected via a 4-core cable. The cable ends of the
Pilz ready-made cable are colour-coded. Please refer to the table below
for the coding details.
Pin assignment of M12 connector X3 on the transmitter
6.2.3 Supply voltage
Supply voltage6-Verdrahtung_Anschluss_Versorgungsspannung
The supply voltage is fed to the receiver and transmitter via the 8-core /
4-core connection cable.
6.2.4 Connection between transmitter and receiver
Connection between transmitter and receiver6-Verdrahtung_Anschluss_Verbildung_Sender_Empfaenger
The signals TRM_ON and TRM_SYNC are routed via the control cabinet.
Pin no. Designation Description Colour
1 24 V DC Input, 24 V DC supply voltage brown
2 TRM_SYNC Input, signal to control the intensity of the light
source
white
3 0 V Input, 0 V supply voltage blue
4 TRM_ON Input, signal to switch the light source on and off Black
Shield Cable shielding
1
2
3
4