Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
11-1
11.1 Technical Details
11 Technical Details
1111000Technical DetailsTechnical Details11-11.1Technical Details1110 0Technical Details11-Technische Daten PSENvip RL D M
Technical details
Function Camera-based protection system with integrated overrun
measurement
Application area IEC 61496-1,-2, prEN 12622, IEC 61508
Detection zone
Length 0.1 m … 10 m
Height Max. 20 mm
Width 44 mm
Reaction time 4 ms
Category Type 4 in accordance with IEC 61496-1
Resolution of protected field
Object size 7 mm
Overrun 2 mm
Required penetration depth
From side 1.6 mm
From top or bottom 1.6 mm
Overrun measurement 2 mm … 14 mm
Transmitter's electrical data
Number of inputs 2
Supply voltage 24 VDC
Tolerance range 20 V … 30 VDC including residual ripple of max. ± 1.2 V
Current consumption 0.2 A at 24 VDC
Connection type M12, 4-pin
Cable cross section Min. 0.14 mm
Light source High Power LED
Service life 50 000 hours
Diameter of illuminated target area 70 mm
Receiver's electrical data
Supply voltage 24 VDC
Tolerance range 20 V … 30 VDC including residual ripple of max. ± 1.2 V
Current consumption Max. 2 A at 24 VDC
Connection type 2 x M12, 8-pin
Inputs on the receiver
Number 5
Galvanic isolation No
Signal level at "0" -3 V … +5 VDC
Signal level at "1" +15 V … +30 VDC
Input current Typ. 6 mA
Recognition time Min. 100 ms
Outputs on the receiver
Number of positive-switching single-pole semiconductor
outputs
8
Galvanic isolation No
Output current at "1" Max. 0.25 A at 24 VDC
Permitted range 0 ... 0.32 A
Short circuit protection Electronic
Min. pulse width at "0" signal (off time) 100 ms
Max. cable length with cable cross section 0.25 mm
2
150 m