Pilz PSENvip RL D P Manual do Utilizador Página 59

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 58
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-31
4.6 Operating modes during commissioning
4 Function Description
4.6.3 Adjustment during tool change
Adjustment during tool change4-Funktion_Betriebsarten_Inbetriebnahme_Justage_Werkzeugwechsel_1
The tool is assigned to a tool class in "Tool change" operating mode.
Once the tool data has been saved it is downloaded to the safety sys-
tem.
Funktion_Betriebsarten_Inbetriebnahme_Justage_Werkzeugwechsel
The adjustment line is automatically tracked to the tip of the tool. The
tracking is shown on the display. This makes it easier to adjust to the dif-
ferent tool sizes.
In this operating mode
The protected field is inactive.
The OSSDs are switched off.
There is no protection via the PSENvip.
4.6.4 Setting the parameters for bending angle measurement
Setting the parameters for bending angle measurement4-Funktion_Betriebsarten_Inbetriebnahme_Biegewinkelmessung
Set and tolerance values for a maximum of 5 angles can be set for bend-
ing angle measurement.
INFORMATION
Generally you should not have to mechanically realign the trans-
mitter and receiver during a tool change.
INFORMATION
Details of the adjustments made during a tool change are
described in Chapter 7, "Commissioning", section entitled
"Adjustment during tool change".
INFORMATION
Details for setting the parameters for bending angle measure-
ment are given in Chapter 7, "Commissioning", under "Setting
the parameters for bending angle measurement".